Enter your product and environment information to create an Installation and Upgrade checklist. | |
---|---|
Product: | |
Product version you are installing or upgrading to: | |
Platform: | |
Processor: | |
Product version you are upgrading from (optional): | |
Enter your product and environment information to create an Installation and Upgrade checklist. | |
---|---|
Product: | |
Product version you are installing or upgrading to: | |
Platform: | |
Processor: | |
Product version you are upgrading from (optional): | |
Custom Reports Using Data Collectors
View Control | |
Use "Collapse all" to hide all sections, or "Expand all" to show all sections. | Collapse all |
Installation options | Required disk space |
SF + all options | 1124 MB |
SF Client components | 632 MB |
Release Date(GA) | Extended Support Starts | Sustaining Support Starts | End of Support Life Date(EOSL) |
---|---|---|---|
2011-12-18 | 2018-12-01 | 2020-12-30 | 2026-12-30 |
Edition | Version | Notes |
---|---|---|
Windows Server 2008 R2 Standard, Enterprise or Datacenter Edition | GA or SP1 | The support 2008 R2 includes Server Core versions. |
Windows Server 2008 R2 Standard, Enterprise or Datacenter Edition with or without Hyper-V (guest or parent) | GA or SP1 |
Edition | Version | Notes |
---|---|---|
Windows Web Server 2008 R2 | GA or SP1 | DMP Option is not supported on Windows Web Server 2008 because Microsoft does not have the MPIO component on this edition. |
Windows Storage Server 2008 R2 | N/A |
OS | HBA model | iSCSI software initiator version |
---|---|---|
Microsoft Windows | Microsoft iSCSI Software Initiator [1] | 2.07 or above |
Documentation |
Array | Mode | Interface | Note |
---|---|---|---|
E-Class, S-Class | A/A | Fibre Channel | * Consult 3PAR's Configuration Matrix for interoperability and space reclamation support. * More 3PAR array systems support information is under the HP section. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
Array | Mode | Interface | Note |
---|---|---|---|
Celerra series | A/A-A | Fibre Channel | |
Celerra series | A/P-C | Fibre Channel | |
CLARiiON AX series | A/A-A | Fibre Channel | * Supports CLARiiON AX4 only. |
CLARiiON AX series | A/A-A | iSCSI | * Supports CLARiiON AX4 only. |
CLARiiON AX series with PowerPath | A/A-A | Fibre Channel | * Supports CLARiiON AX4 only. |
CLARiiON AX series with PowerPath | A/A-A | iSCSI | * Supports CLARiiON AX4 only. |
CLARiiON AX series | A/P-C | Fibre Channel | * Supports CLARiiON AX4 only. |
CLARiiON AX series | A/P-C | iSCSI | * Supports CLARiiON AX4 only. |
CLARiiON AX series with PowerPath | A/P-C | Fibre Channel | * Supports CLARiiON AX4 only. |
CLARiiON AX series with PowerPath | A/P-C | iSCSI | * Supports CLARiiON AX4 only. |
CLARiiON CX series | A/A-A | Fibre Channel | |
CLARiiON CX series with PowerPath | A/A-A | Fibre Channel | |
CLARiiON CX series | A/P-C | Fibre Channel | |
CLARiiON CX series with PowerPath | A/P-C | Fibre Channel | |
CLARiiON CX3 series | A/A-A | Fibre Channel | |
CLARiiON CX3 series | A/A-A | iSCSI | |
CLARiiON CX3 series with PowerPath | A/A-A | Fibre Channel | |
CLARiiON CX3 series with PowerPath | A/A-A | iSCSI | |
CLARiiON CX3 series | A/P-C | Fibre Channel | |
CLARiiON CX3 series | A/P-C | iSCSI | |
CLARiiON CX3 series with PowerPath | A/P-C | Fibre Channel | |
CLARiiON CX3 series with PowerPath | A/P-C | iSCSI | |
CLARiiON CX4 series | A/A-A | Fibre Channel | |
CLARiiON CX4 series | A/A-A | iSCSI | |
CLARiiON CX4 series with PowerPath | A/A-A | Fibre Channel | |
CLARiiON CX4 series with PowerPath | A/A-A | iSCSI | |
CLARiiON CX4 series | A/P-C | Fibre Channel | |
CLARiiON CX4 series | A/P-C | iSCSI | |
CLARiiON CX4 series with PowerPath | A/P-C | Fibre Channel | |
CLARiiON CX4 series with PowerPath | A/P-C | iSCSI | |
EqualLogic PS5000 series | A/A | iSCSI | * There is a known problem of IO hang sometimes when a NIC port is disabled on the Switch. Also, it is recommended to use 2 NICs for private heartbeat and a separate NIC for public-mix use or client-only use in MSCS environments due to a known issue when Private NICs are used for private heartbeat and other types of traffic. |
EqualLogic PS6000 series | A/A | iSCSI | |
PowerMax series | A/A | Fibre Channel | |
PowerVault MD32xx Series | A/P-C | iSCSI | |
PowerVault MD32xx Series | A/P-C | SAS | |
PowerVault MD36xx Series | A/P-C | Fibre Channel | |
PowerVault MD36xx Series | A/P-C | iSCSI | |
PowerVault MD38xx Series | A/P-C | Fibre Channel | * Requires CP5 or higher for VDID or Enclosure discovery. |
SC Series | A/A | Fibre Channel | * Support Storage Center OS (SCOS) software version 6.2.2 and higher. |
SC Series | A/A | iSCSI | * Support Storage Center OS (SCOS) software version 6.2.2 and higher. |
ScaleIO | A/A | Ethernet | |
Symmetrix 3000 series | A/A | Fibre Channel | |
Symmetrix 3000 series with PowerPath | A/A | Fibre Channel | |
Symmetrix 8000 series | A/A | Fibre Channel | * Requires firmware version 5568.67 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
Symmetrix 8000 series with PowerPath | A/A | Fibre Channel | |
Symmetrix DMX series | A/A | Fibre Channel | * Requires firmware version 5670.73 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * Supports Symmetrix DMX-3 and Symmetrix DMX-4 only. |
Symmetrix DMX series with PowerPath | A/A | Fibre Channel | * Supports Symmetrix DMX-3 and Symmetrix DMX-4 only. |
Symmetrix VMAX series | A/A | FCoE | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
Symmetrix VMAX series | A/A | Fibre Channel | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
Symmetrix VMAX series | A/A | iSCSI | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
Symmetrix VMAX series with PowerPath | A/A | Fibre Channel | |
Unity series | A/A-A | Fibre Channel | |
Unity series with PowerPath | A/A-A | Fibre Channel | |
VMAX3/VMAX All Flash Family series | A/A | Fibre Channel | |
VMAX3/VMAX All Flash Family series with PowerPath | A/A | Fibre Channel | |
VNX series | A/A-A | Fibre Channel | * Supported with block mode storage only. |
VNX series | A/A-A | iSCSI | * Supported with block mode storage only. |
VNX series with PowerPath | A/A-A | Fibre Channel | |
VNX series | A/P-C | Fibre Channel | * Supported with block mode storage only. |
VNX series | A/P-C | iSCSI | * Supported with block mode storage only. |
VNX series with PowerPath | A/P-C | Fibre Channel | |
VNX2 series | A/A-A | Fibre Channel | * Supported with block mode storage only. |
VNX2 series with PowerPath | A/A-A | Fibre Channel | |
VNX2e series | A/A-A | Fibre Channel | |
VPLEX | A/A | Fibre Channel | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
VPLEX with PowerPath | A/A | Fibre Channel | |
XtremIO | A/A | FCoE | |
XtremIO | A/A | Fibre Channel | |
XtremIO | A/A | iSCSI |
Array | Mode | Interface | Note |
---|---|---|---|
ETERNUS DX400/DX500/DX600 series | A/A | Fibre Channel | * A minimum version of 6.0.1 is required to support Thin Reclamation with this array. There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. * Ensure proper array settings are configured to support this mode. * Fujitsu Storage Cluster is not supported. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. |
ETERNUS DX400/DX500/DX600 series | A/A-A | Fibre Channel | * A minimum version of 6.0.1 is required to support Thin Reclamation with this array. There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. * Ensure proper array settings are configured to support this mode. * Fujitsu Storage Cluster is not supported. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. |
ETERNUS DX60/DX80/DX90/DX100/DX200 series | A/A | Fibre Channel | * A minimum version of 6.0.1 is required to support Thin Reclamation with this array. There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. * Ensure proper array settings are configured to support this mode. * Fujitsu Storage Cluster is not supported. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. * Thin Reclamation is not supported with ETERNUS DX60/DX60 S2/DX80/DX90. |
ETERNUS DX60/DX80/DX90/DX100/DX200 series | A/A-A | Fibre Channel | * A minimum version of 6.0.1 is required to support Thin Reclamation with this array. There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. * Ensure proper array settings are configured to support this mode. * Fujitsu Storage Cluster is not supported. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. * Thin Reclamation is not supported with ETERNUS DX60/DX60 S2/DX80/DX90. |
ETERNUS DX8000 S3/S4 series | A/A | Fibre Channel | * A minimum version of 6.0.1 is required to support Thin Reclamation with this array. There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. * Ensure proper array settings are configured to support this mode. * Fujitsu Storage Cluster is not supported. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. |
ETERNUS DX8000 S3/S4 series | A/A-A | Fibre Channel | * A minimum version of 6.0.1 is required to support Thin Reclamation with this array. There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. * Ensure proper array settings are configured to support this mode. * Fujitsu Storage Cluster is not supported. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. |
ETERNUS DX8000 series | A/A | Fibre Channel | * A minimum version of 6.0.1 is required to support Thin Reclamation with this array. There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. * Ensure proper array settings are configured to support this mode. * Fujitsu Storage Cluster is not supported. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. |
ETERNUS DX8000 series | A/A-A | Fibre Channel | * A minimum version of 6.0.1 is required to support Thin Reclamation with this array. There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. * Ensure proper array settings are configured to support this mode. * Fujitsu Storage Cluster is not supported. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. |
ETERNUS VS850 | A/A-A | Fibre Channel | |
ETERNUS VS850 with Subsystem Device Driver | A/A-A | Fibre Channel | |
ETERNUS2000 series | A/A | Fibre Channel | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
ETERNUS4000 series | A/A | Fibre Channel | * A minimum version of 6.0.1 is required to support Thin Reclamation with this array. There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. * Excludes ETERNUS4000 models 80 and 100. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. |
ETERNUS6000 series | A/A | Fibre Channel | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
ETERNUS8000 series | A/A | Fibre Channel | * A minimum version of 6.0.1 is required to support Thin Reclamation with this array. There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * There are known issues with Reclamation, see http://www.veritas.com/docs/TECH164853 for more details. |
Array | Mode | Interface | Note |
---|---|---|---|
2000 G2 series | A/A-A | Fibre Channel | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
2000 G2 series | A/A-A | iSCSI | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
2000 G2 series | A/A-A | SAS | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
3PAR F/T-Class, StoreServ 7000/8000/9000/10000/20000 Storage | A/A | Fibre Channel | * 3PAR F/T-Class maximum firmware version is 3.1.3; 3PAR StoreServ 7000/10000 minimum firmware version 3.1.2 and StoreServ 8000/20000 minimum firmware version 3.2.2 are required. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * StoreServ 8000/20000 minimum firmware version 3.2.2 MU1 is required for Thin Reclamation support. |
EVA GL 3000/5000 | A/A-A | Fibre Channel | * Active/Active array firmware is required. Contact your local HP representative for more information. * Requires firmware version 4.004 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
EVA4000/6000/8000 | A/A-A | Fibre Channel | * Requires firmware version 5030 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * When utilizing the HP EVA arrays with SFW DMP, iSCSI is supported when used with the HP EVA iSCSI Connectivity Option. However, Active/Active Load Balancing algorithms are not supported in this configuration because SCSI-3 Persistent Reservation is not supported with the EVA iSCSI Connectivity Option at this point in time. Therefore, SCSI-3 support cannot be used and must be disabled in the system registry or system wide in the Symantec Enterprise Administrator (VEA) Control Panel System Settings when the EVA iSCSI Connectivity Option, by itself or in combination with other arrays, is connected to a host. |
EVA4000/6000/8000 | A/A-A | iSCSI | * Requires firmware version 5030 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * When utilizing the HP EVA arrays with SFW DMP, iSCSI is supported when used with the HP EVA iSCSI Connectivity Option. However, Active/Active Load Balancing algorithms are not supported in this configuration because SCSI-3 Persistent Reservation is not supported with the EVA iSCSI Connectivity Option at this point in time. Therefore, SCSI-3 support cannot be used and must be disabled in the system registry or system wide in the Symantec Enterprise Administrator (VEA) Control Panel System Settings when the EVA iSCSI Connectivity Option, by itself or in combination with other arrays, is connected to a host. |
EVA4100/6100/8100 | A/A-A | Fibre Channel | * Requires firmware version 5030 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * When utilizing the HP EVA arrays with SFW DMP, iSCSI is supported when used with the HP EVA iSCSI Connectivity Option. However, Active/Active Load Balancing algorithms are not supported in this configuration because SCSI-3 Persistent Reservation is not supported with the EVA iSCSI Connectivity Option at this point in time. Therefore, SCSI-3 support cannot be used and must be disabled in the system registry or system wide in the Symantec Enterprise Administrator (VEA) Control Panel System Settings when the EVA iSCSI Connectivity Option, by itself or in combination with other arrays, is connected to a host. |
EVA4100/6100/8100 | A/A-A | iSCSI | * Requires firmware version 5030 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * When utilizing the HP EVA arrays with SFW DMP, iSCSI is supported when used with the HP EVA iSCSI Connectivity Option. However, Active/Active Load Balancing algorithms are not supported in this configuration because SCSI-3 Persistent Reservation is not supported with the EVA iSCSI Connectivity Option at this point in time. Therefore, SCSI-3 support cannot be used and must be disabled in the system registry or system wide in the Symantec Enterprise Administrator (VEA) Control Panel System Settings when the EVA iSCSI Connectivity Option, by itself or in combination with other arrays, is connected to a host. |
EVA4400/6400/8400 series | A/A-A | Fibre Channel | * Requires firmware version 5030 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
MSA 1040 SAN | A/A-A | Fibre Channel | |
MSA 2040 SAN | A/A-A | Fibre Channel | |
MSA 2040 SAN | A/A-A | iSCSI | |
MSA 2040 SAN | A/A-A | SAS | |
MSA P2000 | A/A-A | Fibre Channel | |
MSA1000 | A/A | Fibre Channel | |
MSA1500 | A/A | Fibre Channel | * Active/Active array firmware is required. Contact your local HP representative for more information. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
MSA2000fc series | A/A | Fibre Channel | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
MSA2012i | A/A | iSCSI | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
MSA2012sa | A/A | SAS | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
MSA2212i | A/A | iSCSI | |
MSA2212sa | A/A | SAS | |
P2000 G3 MSA series | A/A-A | Fibre Channel | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * There is a known issue with support for HP P2000 G3 MSA series arrays where disabling all but 1 active path to the lun causes disk missing from the server. |
P2000 G3 MSA series | A/A-A | iSCSI | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * There is a known issue with support for HP P2000 G3 MSA series arrays where disabling all but 1 active path to the lun causes disk missing from the server. |
P2000 G3 MSA series | A/A-A | SAS | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. * There is a known issue with support for HP P2000 G3 MSA series arrays where disabling all but 1 active path to the lun causes disk missing from the server. |
P6000 EVA series | A/A-A | FCoE | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
P6000 EVA series | A/A-A | Fibre Channel | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
P6000 EVA series | A/A-A | iSCSI | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
P9500 | A/A | Fibre Channel | * Requires firmware version 70-01-04-00/00 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
XP10000/12000 | A/A | Fibre Channel | * Requires firmware version 50-01-40-00/00 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
XP128/1024 | A/A | Fibre Channel | * Requires firmware version 21-09-15 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
XP20000/24000 | A/A | Fibre Channel | |
XP48 | A/A | Fibre Channel | |
XP512 | A/A | Fibre Channel | |
XP7 series | A/A | Fibre Channel |
Array | Mode | Interface | Note |
---|---|---|---|
AMS/WMS series | A/P-C | Fibre Channel | |
AMS/WMS series with HDLM (Hitachi Dynamic Link Manager) | A/P-C | Fibre Channel | |
HUS 100 series | A/A | Fibre Channel | |
HUS 100 series with HDLM (Hitachi Dynamic Link Manager) | A/A | Fibre Channel | |
HUS VM | A/A | Fibre Channel | |
HUS VM with HDLM (Hitachi Dynamic Link Manager) | A/A | Fibre Channel | |
Lightning 9900V series | A/A | Fibre Channel | * Requires firmware version 21-10-13-00/00 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
Lightning 9900V series with HDLM (Hitachi Dynamic Link Manager) | A/A | Fibre Channel | |
SANRISE H12000 | A/A | Fibre Channel | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
SANRISE H12000 with HDLM (Hitachi Dynamic Link Manager) | A/A | Fibre Channel | |
SMS/AMS2000 series | A/A | Fibre Channel | * Excludes SMS100. * SMS does not support Thin Provisioning. |
SMS/AMS2000 series | A/A | iSCSI | * Excludes SMS100. * SMS does not support Thin Provisioning. |
SMS/AMS2000 series with HDLM (Hitachi Dynamic Link Manager) | A/A | Fibre Channel | * Excludes SMS100. |
SMS/AMS2000 series with HDLM (Hitachi Dynamic Link Manager) | A/A | iSCSI | * Excludes SMS100. |
Thunder 9500V series | A/P-C | Fibre Channel | * During a Hitachi online format of new LUNS, certain SCSI commands are disabled which may temporarily suspend data access. Contact Hitachi for a list of these commands. |
Thunder 9500V series with HDLM (Hitachi Dynamic Link Manager) | A/P-C | Fibre Channel | |
USP/NSC series | A/A | Fibre Channel | * Requires firmware version 50-05-22-00/00 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
USP/NSC series with HDLM (Hitachi Dynamic Link Manager) | A/A | Fibre Channel | |
USPV/USPVM | A/A | Fibre Channel | |
USPV/USPVM with HDLM (Hitachi Dynamic Link Manager) | A/A | Fibre Channel | |
VSP | A/A | Fibre Channel | * Requires firmware version 70-01-04-00/00 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
VSP with HDLM (Hitachi Dynamic Link Manager) | A/A | Fibre Channel | |
VSP G series | A/A | Fibre Channel | |
VSP G series with HDLM (Hitachi Dynamic Link Manager) | A/A | Fibre Channel | |
VSP Gx00/Fx00 series | A/A | Fibre Channel |
Array | Mode | Interface | Note |
---|---|---|---|
18000 series | A/A | Fibre Channel | * For Huawei 18000 A/A, MS KB http://support.microsoft.com/kb/2522766 is required. Check "Prerequisites" of the KB to install MS KB. |
OceanStor Series | A/A-A | Fibre Channel | * DDI Q1 2013 is the minimum version required to support Huawei Dorado5100 and Huawei S2200T storage arrays. * For OceanStor V3 models, MS KB http://support.microsoft.com/kb/2522766 is required. Check "Prerequisites" of the KB to install MS KB. * Thin Reclamation is only supported with OceanStor Series with volumes track aligned to 2048 sectors, the ALUA explicit trespass on Thin LUN is not supported. |
OceanStor Series | A/A-A | iSCSI | * DDI Q1 2013 is the minimum version required to support Huawei Dorado5100 and Huawei S2200T storage arrays. * For OceanStor V3 models, MS KB http://support.microsoft.com/kb/2522766 is required. Check "Prerequisites" of the KB to install MS KB. * Thin Reclamation is only supported with OceanStor Series with volumes track aligned to 2048 sectors, the ALUA explicit trespass on Thin LUN is not supported. |
S5000 series | A/P-C | Fibre Channel | |
VIS series | A/A | Fibre Channel |
Array | Mode | Interface | Note |
---|---|---|---|
DS3950 | A/P-C | Fibre Channel | * IMPORTANT: These arrays require additional configuration steps in order to work properly with Symantec Storage Foundation for Windows. Before attempting to use any of these arrays with Symantec Storage Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP, including Auto Volume Transfer (AVT), also referred to as Auto Logical Drive Transfer (ADT). Specific firmware levels from the manufacturer for these arrays may also be required. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
DS3950 with DS Storage Manager | A/P-C | Fibre Channel | |
DS5020 | A/P-C | Fibre Channel | * IMPORTANT: These arrays require additional configuration steps in order to work properly with Symantec Storage Foundation for Windows. Before attempting to use any of these arrays with Symantec Storage Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP, including Auto Volume Transfer (AVT), also referred to as Auto Logical Drive Transfer (ADT). Specific firmware levels from the manufacturer for these arrays may also be required. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
DS5020 with DS Storage Manager | A/P-C | Fibre Channel | |
ESS 750/800 series | A/A | Fibre Channel | * Requires firmware version 2.3.2.71 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
ESS 750/800 series with Subsystem Device Driver | A/A | Fibre Channel | * IBM SDD Version 2.4.2.0-1 is not supported, there are known issues of Blue screen (BSOD) during use of this version of the driver. |
FlashSystem series | A/A | Fibre Channel | * Supports FlashSystem 840/900 models. |
Spectrum Virtualize series | A/A-A | Fibre Channel | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
Spectrum Virtualize series | A/A-A | iSCSI | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
Spectrum Virtualize series with Subsystem Device Driver | A/A-A | Fibre Channel | |
Storwize series | A/A-A | Fibre Channel | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
Storwize series | A/A-A | iSCSI | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
Storwize series with Subsystem Device Driver | A/A-A | Fibre Channel | * IBM SDD Version 2.4.2.0-1 is not supported, there are known issues of Blue screen (BSOD) during use of this version of the driver. |
System Storage DS3000 series | A/P-C | Fibre Channel | * IMPORTANT: These arrays require additional configuration steps in order to work properly with Symantec Storage Foundation for Windows. Before attempting to use any of these arrays with Symantec Storage Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP, including Auto Volume Transfer (AVT), also referred to as Auto Logical Drive Transfer (ADT). Specific firmware levels from the manufacturer for these arrays may also be required. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
System Storage DS3000 series | A/P-C | iSCSI | * IMPORTANT: These arrays require additional configuration steps in order to work properly with Symantec Storage Foundation for Windows. Before attempting to use any of these arrays with Symantec Storage Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP, including Auto Volume Transfer (AVT), also referred to as Auto Logical Drive Transfer (ADT). Specific firmware levels from the manufacturer for these arrays may also be required. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
System Storage DS3000 series | A/P-C | SAS | * IMPORTANT: These arrays require additional configuration steps in order to work properly with Symantec Storage Foundation for Windows. Before attempting to use any of these arrays with Symantec Storage Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP, including Auto Volume Transfer (AVT), also referred to as Auto Logical Drive Transfer (ADT). Specific firmware levels from the manufacturer for these arrays may also be required. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
System Storage DS3500 series | A/P-C | Fibre Channel | * IMPORTANT: These arrays require additional configuration steps in order to work properly with Symantec Storage Foundation for Windows. Before attempting to use any of these arrays with Symantec Storage Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP, including Auto Volume Transfer (AVT), also referred to as Auto Logical Drive Transfer (ADT). Specific firmware levels from the manufacturer for these arrays may also be required. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
System Storage DS3500 series | A/P-C | iSCSI | * IMPORTANT: These arrays require additional configuration steps in order to work properly with Symantec Storage Foundation for Windows. Before attempting to use any of these arrays with Symantec Storage Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP, including Auto Volume Transfer (AVT), also referred to as Auto Logical Drive Transfer (ADT). Specific firmware levels from the manufacturer for these arrays may also be required. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
System Storage DS3500 series | A/P-C | SAS | * IMPORTANT: These arrays require additional configuration steps in order to work properly with Symantec Storage Foundation for Windows. Before attempting to use any of these arrays with Symantec Storage Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP, including Auto Volume Transfer (AVT), also referred to as Auto Logical Drive Transfer (ADT). Specific firmware levels from the manufacturer for these arrays may also be required. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
System Storage DS5000 series | A/P-C | Fibre Channel | * IMPORTANT: These arrays require additional configuration steps in order to work properly with Symantec Storage Foundation for Windows. Before attempting to use any of these arrays with Symantec Storage Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP, including Auto Volume Transfer (AVT), also referred to as Auto Logical Drive Transfer (ADT). Specific firmware levels from the manufacturer for these arrays may also be required. * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
System Storage DS5000 series with DS Storage Manager | A/P-C | Fibre Channel | |
System Storage DS6000 series | A/A-A | Fibre Channel | * Requires firmware version 6.1.600.46 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
System Storage DS6000 series with Subsystem Device Driver | A/A-A | Fibre Channel | * IBM SDD Version 2.4.2.0-1 is not supported, there are known issues of Blue screen (BSOD) during use of this version of the driver. |
System Storage DS8000 series | A/A | Fibre Channel | * Requires firmware version 6.1.600.46 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
System Storage DS8000 series with Subsystem Device Driver | A/A | Fibre Channel | * IBM SDD Version 2.4.2.0-1 is not supported, there are known issues of Blue screen (BSOD) during use of this version of the driver. |
System Storage N series | A/A-A | Fibre Channel | * Requires ONTAP version 7.0.2 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
System Storage N series | A/A-A | iSCSI | * Requires ONTAP version 7.0.2 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
System Storage N series | A/P-C | Fibre Channel | * Requires ONTAP version 7.0.2 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
System Storage N series | A/P-C | iSCSI | * Requires ONTAP version 7.0.2 or higher to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
System Storage XIV series | A/A | Fibre Channel | * Excludes A9000 & A9000R models. * To obtain Clustering support with IBM XIV, a minimum Firmware level of 10.0.1.c is required. |
TotalStorage DS4000 series | A/P-C | Fibre Channel | * IMPORTANT: These arrays require additional configuration steps in order to work properly with Symantec Storage Foundation for Windows. Before attempting to use any of these arrays with Symantec Storage Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP, including Auto Volume Transfer (AVT), also referred to as Auto Logical Drive Transfer (ADT). Specific firmware levels from the manufacturer for these arrays may also be required. |
TotalStorage DS4000 series with DS Storage Manager | A/P-C | Fibre Channel |
Array | Mode | Interface | Note |
---|---|---|---|
Nexsan E-Series Systems | A/A | Fibre Channel |
Array | Mode | Interface | Note |
---|---|---|---|
InfiniBox F-Series | A/A | Fibre Channel |
Array | Mode | Interface | Note |
---|---|---|---|
DC P3700 | A/A | PCIe | |
SSD 910 | A/A | PCIe |
Array | Mode | Interface | Note |
---|---|---|---|
AFF Series | A/A-A | Fibre Channel | * A minimum version of ONTAP 8.3 is required to support this array. |
AFF Series | A/A-A | iSCSI | * A minimum version of ONTAP 8.3 is required to support this array. |
FAS2000/FAS900/FAS200 series | A/A-A | Fibre Channel | * Storage Foundation 6.0.x supports configurations that run Clustered Data ONTAP (cDOT) version 8.2.1 or greater with a limitation of TWO Controller Nodes only. * Storage Foundation 6.1 supports configurations that run Clustered Data ONTAP (cDOT) version 8.2.1 or greater with a limitation of TWO Controller Nodes only. * There is a known issue with support for NetApp arrays. When the interconnect cable between the filers is disconnected, the servers get rebooted and stay at boot prompt until the cable is reconnected and servers are rebooted. |
FAS2000/FAS900/FAS200 series | A/A-A | iSCSI | * Storage Foundation 6.0.x supports configurations that run Clustered Data ONTAP (cDOT) version 8.2.1 or greater with a limitation of TWO Controller Nodes only. * Storage Foundation 6.1 supports configurations that run Clustered Data ONTAP (cDOT) version 8.2.1 or greater with a limitation of TWO Controller Nodes only. * There is a known issue with support for NetApp arrays. When the interconnect cable between the filers is disconnected, the servers get rebooted and stay at boot prompt until the cable is reconnected and servers are rebooted. |
FAS2000/FAS900/FAS200 series | A/P-C | Fibre Channel | * There is a known issue with support for NetApp arrays. When the interconnect cable between the filers is disconnected, the servers get rebooted and stay at boot prompt until the cable is reconnected and servers are rebooted. |
FAS2000/FAS900/FAS200 series | A/P-C | iSCSI | * There is a known issue with support for NetApp arrays. When the interconnect cable between the filers is disconnected, the servers get rebooted and stay at boot prompt until the cable is reconnected and servers are rebooted. |
FAS3000/V3000 series | A/A-A | Fibre Channel | * Storage Foundation 6.0.x supports configurations that run Clustered Data ONTAP (cDOT) version 8.2.1 or greater with a limitation of TWO Controller Nodes only. * Storage Foundation 6.1 supports configurations that run Clustered Data ONTAP (cDOT) version 8.2.1 or greater with a limitation of TWO Controller Nodes only. * There is a known issue with support for NetApp arrays. When the interconnect cable between the filers is disconnected, the servers get rebooted and stay at boot prompt until the cable is reconnected and servers are rebooted. |
FAS3000/V3000 series | A/A-A | iSCSI | * Storage Foundation 6.0.x supports configurations that run Clustered Data ONTAP (cDOT) version 8.2.1 or greater with a limitation of TWO Controller Nodes only. * Storage Foundation 6.1 supports configurations that run Clustered Data ONTAP (cDOT) version 8.2.1 or greater with a limitation of TWO Controller Nodes only. * There is a known issue with support for NetApp arrays. When the interconnect cable between the filers is disconnected, the servers get rebooted and stay at boot prompt until the cable is reconnected and servers are rebooted. |
FAS3000/V3000 series | A/P-C | Fibre Channel | * There is a known issue with support for NetApp arrays. When the interconnect cable between the filers is disconnected, the servers get rebooted and stay at boot prompt until the cable is reconnected and servers are rebooted. |
FAS3000/V3000 series | A/P-C | iSCSI | * There is a known issue with support for NetApp arrays. When the interconnect cable between the filers is disconnected, the servers get rebooted and stay at boot prompt until the cable is reconnected and servers are rebooted. |
FAS6000/V6000 series | A/A-A | Fibre Channel | * Storage Foundation 6.0.x supports configurations that run Clustered Data ONTAP (cDOT) version 8.2.1 or greater with a limitation of TWO Controller Nodes only. * Storage Foundation 6.1 supports configurations that run Clustered Data ONTAP (cDOT) version 8.2.1 or greater with a limitation of TWO Controller Nodes only. * There is a known issue with support for NetApp arrays. When the interconnect cable between the filers is disconnected, the servers get rebooted and stay at boot prompt until the cable is reconnected and servers are rebooted. |
FAS6000/V6000 series | A/A-A | iSCSI | * Storage Foundation 6.0.x supports configurations that run Clustered Data ONTAP (cDOT) version 8.2.1 or greater with a limitation of TWO Controller Nodes only. * Storage Foundation 6.1 supports configurations that run Clustered Data ONTAP (cDOT) version 8.2.1 or greater with a limitation of TWO Controller Nodes only. * There is a known issue with support for NetApp arrays. When the interconnect cable between the filers is disconnected, the servers get rebooted and stay at boot prompt until the cable is reconnected and servers are rebooted. |
FAS6000/V6000 series | A/P-C | Fibre Channel | * There is a known issue with support for NetApp arrays. When the interconnect cable between the filers is disconnected, the servers get rebooted and stay at boot prompt until the cable is reconnected and servers are rebooted. |
FAS6000/V6000 series | A/P-C | iSCSI | * There is a known issue with support for NetApp arrays. When the interconnect cable between the filers is disconnected, the servers get rebooted and stay at boot prompt until the cable is reconnected and servers are rebooted. |
FAS8000/FAS9000 Series | A/A-A | Fibre Channel | * Storage Foundation 6.0.x supports configurations that run Clustered Data ONTAP (cDOT) version 8.2.1 or greater with a limitation of TWO Controller Nodes only. * Storage Foundation 6.1 supports configurations that run Clustered Data ONTAP (cDOT) version 8.2.1 or greater with a limitation of TWO Controller Nodes only. |
FAS8000/FAS9000 Series | A/A-A | iSCSI | * Storage Foundation 6.0.x supports configurations that run Clustered Data ONTAP (cDOT) version 8.2.1 or greater with a limitation of TWO Controller Nodes only. * Storage Foundation 6.1 supports configurations that run Clustered Data ONTAP (cDOT) version 8.2.1 or greater with a limitation of TWO Controller Nodes only. |
FAS8000/FAS9000 Series | A/P-C | Fibre Channel | |
FAS8000/FAS9000 Series | A/P-C | iSCSI | |
GF series | A/A-A | Fibre Channel | |
GF series | A/A-A | iSCSI | |
GF series | A/P-C | Fibre Channel | |
GF series | A/P-C | iSCSI | |
NearStore R100 | A/A-A | Fibre Channel | |
NearStore R100 | A/A-A | iSCSI | |
NearStore R100 | A/P-C | Fibre Channel | |
NearStore R100 | A/P-C | iSCSI |
Array | Mode | Interface | Note |
---|---|---|---|
NexentaStor | A/A-A | Fibre Channel | * DDI Q1 2013 is the minimum version required to support this appliance. |
Array | Mode | Interface | Note |
---|---|---|---|
Beast Systems | A/A | Fibre Channel |
Array | Mode | Interface | Note |
---|---|---|---|
SANARENA 2200 | A/A | Fibre Channel | |
SANARENA 2200 with HDLM (Hitachi Dynamic Link Manager) | A/A | Fibre Channel |
Array | Mode | Interface | Note |
---|---|---|---|
CS/AF/HF-Series | A/P-C | Fibre Channel |
Array | Mode | Interface | Note |
---|---|---|---|
Axiom series | A/A-A | Fibre Channel | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
FS1-2 | A/A-A | Fibre Channel | |
Storage 6580/6780 series | A/P-C | Fibre Channel | |
StorageTek 2500 series | A/P-C | Fibre Channel | |
StorageTek 2500 series | A/P-C | iSCSI | |
StorageTek 2500 series | A/P-C | SAS | |
StorageTek 6140 array | A/P-C | Fibre Channel | |
StorageTek 9900 series | A/A | Fibre Channel | |
StorageTek 9900 series with HDLM (Hitachi Dynamic Link Manager) | A/A | Fibre Channel | |
StorageTek 9985/9990 series | A/A | Fibre Channel | |
StorageTek 9985/9990 series with HDLM (Hitachi Dynamic Link Manager) | A/A | Fibre Channel | |
StorageTek 9985V system | A/A | Fibre Channel | |
StorageTek 9985V system with HDLM (Hitachi Dynamic Link Manager) | A/A | Fibre Channel | |
StorageTek 9990V system | A/A | Fibre Channel | |
StorageTek 9990V system with HDLM (Hitachi Dynamic Link Manager) | A/A | Fibre Channel | |
Sun Storage 6180 array | A/P-C | Fibre Channel | |
ZFS Storage Appliance series | A/A-A | Fibre Channel | * Excludes ZFS Storage ZS4-4. * ZFS Storage ZS3-2 is not supported yet. |
ZFS Storage Appliance series | A/A-A | iSCSI | * Excludes ZFS Storage ZS4-4. * ZFS Storage ZS3-2 is not supported yet. |
Array | Mode | Interface | Note |
---|---|---|---|
FlashArray series | A/A | Fibre Channel |
Array | Mode | Interface | Note |
---|---|---|---|
ioDrive | A/A | PCIe | |
ioDrive2 | A/A | PCIe | |
ioMemory PX600 series | A/A | PCIe | * Patch is required, see https://sort.veritas.com/patch/detail/11064 for SFW 6.0.2 and https://sort.veritas.com/patch/detail/11063 for SFW 6.0.1 for details. * Patch is required, see https://sort.veritas.com/patch/detail/11065 for details. |
ioMemory SX300 series | A/A | PCIe | * Patch is required, see https://sort.veritas.com/patch/detail/11064 for SFW 6.0.2 and https://sort.veritas.com/patch/detail/11063 for SFW 6.0.1 for details. * Patch is required, see https://sort.veritas.com/patch/detail/11065 for details. |
Array | Mode | Interface | Note |
---|---|---|---|
FlexLine 200/300 series | A/P-C | Fibre Channel | * Support for the StorageTek Flexline 300 series Storage Systems includes the FLX380 array only. |
Array | Mode | Interface | Note |
---|---|---|---|
StorageTek 6130 | A/P-C | Fibre Channel | * The Sun StorEdge 6130 array requires additional configuration steps in order to work properly with Symantec Storage Foundation for Windows. Before attempting to use the Sun StorEdge 6130 array with Symantec Storage Foundation for Windows DMP software, please contact the array hardware manufacturer for additional configuration instructions and updates. Several special settings must be enabled on these arrays to allow compatibility with DMP. Specific firmware levels from the manufacturer for these arrays may also be required. |
StorageTek 6540 | A/P-C | Fibre Channel | |
StorEdge 9910/9960 | A/A | Fibre Channel | * Please check with Storage Array Manufacturer's Hardware Compatibility Support Matrices for required firmware to support Active/Active DSM mode in a cluster (VCS/MSCS/WSFC) with this array. |
StorEdge 9910/9960 with HDLM (Hitachi Dynamic Link Manager) | A/A | Fibre Channel |
Array | Mode | Interface | Note |
---|---|---|---|
Violin 3000/6000 series | A/A | Fibre Channel | |
Violin 3000/6000 series | A/A-A | Fibre Channel | * A minimum array firmware version G5.5.1 is required to support ALUA mode. |